1.INTRODUCTION

This product is used in fast solidification by lighting dental resin. It is a new generation of standard developed LED curing light, with humanity intelligent chip, the world advanced high intensity LED light and Li-on rechargeable battery. It can cure all the dental resin in the market nowadays,
 

2.PACKING LIST

Main Body: 1Pc             Light Source:: 1Pc
Charge Base: 1Pc          Adapter: 1Pc

USB cable: 1Pc               Light Protect: 1Pc
Lens: 5pcs                     Test block:2pcs
 

3.TECHNICALPARAMETERS
3.1 Main Unit

 

Battery Voltage

DC3.7V

Battery Capacity

1500mAh

Wave Length

385~515nm

Light Density

P1(9W) ≥ 2300mmw/cm²
P2(5W)≥1200mw/cm²

Charging time

3 hours approx

Weight

550g

Packing size

L205 x W109 x H77mm

 

3.2AC Adapter

Rated input voltage

AC100-240V 50/60Hz

Output voltage

DC 5V/MICRO USB

Output current

1A

 

3.3 Operation Conditions
 

Environment temperature

+5 ℃ ~+40 ℃

Relative humidity

10%~80%RH

Atmospheric pressure

50~106KPa


4.Use Method
4.1 Charge

Put the curing light into the charger base, the blue light is shining one by one. When it is done, all of the blue lights are on.It takes about 3hours. Take care not to charge more than 7hours. Remove the adapter from the power supply after charging.

Note: Can charge with the main unit socket also. When charging, theLED screen show CH; when done, the LED show FU


4.2 Operation Instruction

4.2.1Press M orTbutton to power on.Ifpress ON/OFF button, will light the Light source.
4.2.2 Set up Mode:

P1(9W,≥2300mw/cm²)  The actual measured value 2800mw/cm²

P2(5W,≥1200mw/cm²)
 

4.2.3 Setup Time:P1--1/3/5s

                        P2--6/10/15/20s

4.2.4Press ON/OFF button to light on the LED curing light. Ifsome wrong happened, the LED screen shows Er.

4.2.5 The main unit will power off by itselfif without any operation about 2minuts.
 

Caution: the curing light can not be pointed at the patient's eyes while it is operating. If any accidents happen, go to the hospital immediately
 

5.Precautions

5.1 This machine is precise opticalequipment,it should use in the clean and dry place.

5.2 Remove adapter from the power supply after charge. 5.3 Do not touch the battery electrodes by any metal objects.

6.Cleaning & Sterilization

6.1 Clean

Wipe the main unit with neutral detergent if needed.

6.2 Sterilization

6.2.1 The light source can be high pressure autoclaved. Autoclave it after each use with seal bag.
6.2.2Don't autoclave any parts(the main unit and charging base)other than those that can be subjected to autoclave sterilization.

6.2.3 Autoclave up to a max.135℃. It's recommended to autoclave for 20min at 121℃ or 15 min at 132℃.

Notice: Don't use any solvent such as benzine and thinner for sterilization.

7.Transportation And Storage

1)Lay lightly during transportation, avoid strong shake 2) Storage condition:

a. Ambiance temperature:-10~~40℃b.Relative humidity:≤85%

8.Disposing product

Please consult with dealer from whom you purchased it about waster despoil.

9.Warranty

Manufacturer warrants its products to the original purchaser against defects in material and workmanship under normal practices of installation, use and servicing. This unit is guaranteed for its designated use against original defects in materials and workmanship for a period of 12 months from date of purchasing.